Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.281
Filtrar
1.
Mikrochim Acta ; 191(5): 269, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630309

RESUMO

A molecularly-imprinted electrochemiluminescence sensor was constructed for the determination of fenpropathrin (FPT) by molecular imprinting technology. In this sensing platform, the introduction of CdS@MWCNTs significantly enhanced the initial ECL signal of the luminol-O2 system. Specifically, MWCNTs was used as a carrier to adsorb more CdS, in which CdS acted as a co-reaction promoter for luminescence. Molecularly imprinted polymer (MIP) containing specific recognition sites of FPT was used as the material for selective recognition. With increasing amount of FPT the ECL signal decreased. Under the optimum conditions, the ECL response was linearly related to the logarithm of FPT concentration. The developed ECL sensor allowed for sensitive determination of FPT and exhibited a wide linear range from 1.0 × 10- 10 mol L- 1 to 1.0 × 10- 6 mol L- 1. The limit of detection was 3.3 × 10- 11 mol L- 1 (S/N = 3). It can be used for the detection of FPT in vegetable samples.


Assuntos
Luminescência , Impressão Molecular , Piretrinas , Luminol , Polímeros Molecularmente Impressos
2.
Int J Mol Sci ; 25(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38612632

RESUMO

Bile has emerged as an alternative matrix for toxicological investigation of drugs in suspected forensic cases of overdose in adults and intoxications in children. Toxicological investigation consists in screening and, subsequently, confirming the result with specific techniques, such as liquid chromatography with tandem mass spectrometry (LC-MS/MS). As there is no screening test on the market to test postmortem bile specimens, the novelty of this study was in investigating the applicability of a chemiluminescence immunoassay, designed for other matrices and available on the market, on bile and validate its use, testing the agreement with LC-MS/MS analysis. Bile specimens were obtained from 25 forensic cases of suspected death from overdose and intoxication. Sample preparation for bile screening consists simply in centrifugation and dilution. Confirmation analysis allows simultaneous identification of 108 drugs and was validated on bile. Kappa analysis assessed a perfect agreement (0.81-1) between the assays for benzodiazepines, methadone, opiates, cocaine, oxycodone, cannabinoids, buprenorphine and pregabalin; a substantial agreement (0.41-0.6) was reported for barbiturates. No agreement was assessed for amphetamines, due to an abundance of putrefactive amines in postmortem specimens. In conclusion, this fast and easy immunoassay could be used for initial screening of bile specimens, identifying presence of drugs, except amphetamines, with reliability.


Assuntos
Bile , Overdose de Drogas , Adulto , Criança , Humanos , Cromatografia Líquida , Luminescência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Anfetaminas
3.
Methods Mol Biol ; 2797: 125-143, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38570457

RESUMO

Various biochemical methods have been introduced to detect and characterize KRAS activity and interactions, from which the vast majority is based on luminescence detection in its varying forms. Among these methods, thermal stability assays, using luminophore-conjugated proteins or external environment sensing dyes, are widely used. In this chapter, we describe methods enabling KRAS stability monitoring in vitro, with an emphasis on ligand-induced stability. This chapter focuses mainly on luminescence-based techniques utilizing external dye molecules and fluorescence detection.


Assuntos
Luminescência , Proteínas Proto-Oncogênicas p21(ras) , Proteínas Proto-Oncogênicas p21(ras)/genética , Proteínas/química , Medições Luminescentes , Corantes Fluorescentes/química
4.
Mikrochim Acta ; 191(5): 248, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38587676

RESUMO

Tumor-associated antigen (TAA)-based diagnosis has gained prominence for early tumor screening, treatment monitoring, prognostic assessment, and minimal residual disease detection. However, limitations such as low sensitivity and difficulty in extracting non-specific binding membrane proteins still exist in traditional detection methods. Upconversion luminescence (UCL) exhibits unique physical and chemical properties under wavelength near-infrared light excitation. Rolling circle amplification (RCA) is an efficient DNA amplification technique with amplification factors as high as 105. Therefore, the above two excellent techniques can be employed for highly accurate imaging analysis of tumor cells. Herein, we developed a novel nanoplatform for TAA-specific cell imaging based on UCL and RCA technology. An aptamer-primer complex selectively binds to Mucin 1 (MUC1), one of TAA on cell surface, to trigger RCA reaction, generating a large number of repetitive sequences. These sequences provide lots of binding sites for complementary signal probes, producing UCL from lanthanide-doped upconversion nanoparticles (UCNPs) after releasing quencher group. The experimental results demonstrate the specific attachment of upconversion nanomaterials to cancer cells which express a high level of MUC1, indicating the potential of UCNPs and RCA in tumor imaging.


Assuntos
Luminescência , Ácidos Nucleicos , Diagnóstico por Imagem , Membrana Celular , Técnicas de Amplificação de Ácido Nucleico
5.
Luminescence ; 39(4): e4736, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38590043

RESUMO

In recent trends, radiation falls under the narrowband ultraviolet-B region (305-315 nm) widely used in phototherapy lamp applications in the treatment of skin diseases. In this paper, we report a Gd3+-doped NaYF4 luminescent material synthesized for the first time using the low-temperature co-precipitation method. It crystallized into a face-centred cubic structure, as confirmed by X-ray diffraction characterization techniques and Rietveld refinement. The photoluminescence property of the as-prepared sample shows a highly intense, sharp emission band obtained at 311 nm, which belongs to the narrowband ultraviolet-B region and corresponds to the transition of the 6P7/2→8S7/2 level of the Gd3+ ions under 272 nm excitation (8S7/2 to 6IJ). The transitions of the Gd3+ ions are detected entirely with different concentrations of Gd3+ ions. Scanning electron microscopy analysis indicated that the average particle was 288 nm. The critical distance for energy transfer was calculated to be equal to 11.5017 Å. Dipole-dipole interaction is responsible for energy transfer, as analyzed by Dexter theory. These excellent optical characteristics, together with their highly efficient and low-cost synthesis approach, indicate that synthesized NaYF4:Gd3+ phosphors have excessive potential for phototherapeutic lamp applications.


Assuntos
Luminescência , Fototerapia , Transferência de Energia , Difração de Raios X , Íons
6.
Luminescence ; 39(4): e4737, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38587084

RESUMO

The predominant method for pest control has been the use of pesticides, which have been shown to have detrimental effects on soil, freshwater, and crop quality. Therefore, the development of novel and sustainable crop protection strategies has become increasingly imperative. In this study, a novel orange-red emitting Ba2SrWO6: Sm3+ phosphor was synthesized using the high-temperature solid-state reaction. Under ultraviolet excitation, the phosphors showed obvious emission peaks at 575, 614, and 662 nm. The Ba2SrWO6: Sm3+ was used to fabricate a fluorescence film with polydimethylsiloxane (PDMS), and attracted twice as many insects as the blank control group under 365 nm ultraviolet light. This material holds great potential as a fluorescent agent for insect trapping in the pest control fields of tea, cotton, eggplant, rice, potato, grape, and other agricultural industries. Our findings provide an eco-friendly approach to pest management for the increment of food production.


Assuntos
Luminescência , Óxidos , Samário , Compostos de Cálcio , Titânio
7.
Methods Mol Biol ; 2798: 27-43, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38587734

RESUMO

Singlet oxygen is a reactive oxygen species that causes oxidative damage to plant cells, but intriguingly it can also act as a signalling molecule to reprogram gene expression required to induce plant physiological/cellular responses. Singlet oxygen photosensitization in plants mainly occurs in chloroplasts after the molecular collision of ground-state molecular oxygen with triplet-excited-state chlorophyll. Singlet oxygen direct detection through phosphorescence emission in chloroplasts is a herculean task due to its extremely low luminescence quantum yield. Because of this, indirect alternative methods have been developed for its detection in biological systems, for example, by measuring the changes in the EPR signal or fluorescence intensity of singlet oxygen reaction-based probes. The singlet oxygen chemiluminescence (SOCL) is a chemiluminescence probe with high sensitivity and selectivity towards singlet oxygen and promising use to detect it in living cells without the inconvenience of low stability of the EPR signal of spin probes in the presence of redox compounds, spurious light scattering coming from the light source required for the excitation of fluorescence probes or the light emission of endogenous fluorescent molecules like chlorophyll in chloroplasts. The protocol presented in this chapter describes the first steps to characterizing singlet oxygen production within the biological system under study; this is accomplished through monitoring molecular oxygen consumption by SOCL using a Clark-type oxygen electrode and measuring the chemiluminescence generated by SOCL 1,2-dioxetane using a spectrofluorometer. For singlet oxygen detection within living cells, a version of SOCL with increased membrane permeability (SOCL-CPP) is described.


Assuntos
Luminescência , Oxigênio Singlete , Oxigênio , Clorofila , Corantes Fluorescentes
8.
Nat Commun ; 15(1): 3314, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632229

RESUMO

Chiral recognition of amino acids is very important in both chemical and life sciences. Although chiral recognition with luminescence has many advantages such as being inexpensive, it is usually slow and lacks generality as the recognition module relies on structural complementarity. Here, we show that one single molecular-solid sensor, L-phenylalanine derived benzamide, can manifest the structural difference between the natural, left-handed amino acid and its right-handed counterpart via the difference of room-temperature phosphorescence (RTP) irrespective of the specific chemical structure. To realize rapid and reliable sensing, the doped samples are obtained as nanocrystals from evaporation of the tetrahydrofuran solutions, which allows for efficient triplet-triplet energy transfer to the chiral analytes generated in situ from chiral amino acids. The results show that L-analytes induce strong RTP, whereas the unnatural D-analytes produce barely any afterglow. The method expands the scope of luminescence chiral sensing by lessening the requirement for specific molecular structures.


Assuntos
Aminoácidos , Luminescência , Aminoácidos/química , Temperatura , Estrutura Molecular
9.
Luminescence ; 39(4): e4719, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38637113

RESUMO

The luminescence properties of erbium and yttrium co-doped cadmium difluoride with three different concentrations of yttrium were investigated. First, we synthesized single crystal samples with good optical quality using the Bridgman technique. From the optical absorption spectra, recorded at room temperature, both in the ultraviolet-visible and infrared spectral ranges, Judd-Ofelt analysis was performed based on yttrium concentrations to predict the radiative properties of Er3+ luminescent ions. For the 10% optimum concentration of yttrium, a detailed photoluminescence investigation was carried out. We mainly explored green, red, and near-infrared fluorescence under different excitation wavelengths and presented their highlight spectroscopic characteristics. The desired transitions had relatively high emission cross-sections both under visible and near-infrared excitation. Optical gain followed a similar trend. Furthermore, the dynamic fluorescence study showed a significant increase in the measured lifetime under an 800 nm infrared excitation. The upconversion process under an 800 nm excitation produced quantum efficiency greater than 100% due to the contribution of more than one energy transfer mechanism.


Assuntos
Érbio , Luminescência , Íons , Fluorescência , Érbio/química , Ítrio/química
11.
Chem Commun (Camb) ; 60(33): 4447-4450, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38563651

RESUMO

We have developed an upconversion luminescent ratiometric nanoprobe, specifically designed for detection of biothiols with high sensitivity (∼25 nM) at the single-particle level. Using a single-particle localization and rendering method, this nanoprobe enables super-resolution imaging sensing of biothiols within a confined 22 nm space in living cells.


Assuntos
Diagnóstico por Imagem , Nanopartículas , Luminescência
12.
Anal Methods ; 16(15): 2248-2255, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38568684

RESUMO

Herein, a magnetic bead-based chemiluminescence assay is reported to detect type IV collagen (col-IV) in serum samples. Magnetic beads (MBs) exhibit biocompatibility. Taking advantage of this property, they were conjugated with the col-IV antibody. For the determination of col-IV, the interaction of the col-IV sample, anti-(col-IV)-alkaline phosphatase (anti-(col-IV)-ALP) and anti-col-IV-magnetic beads (anti-(col-IV)-MBs) was performed to generate chemiluminescence. Under the optimized conditions, the developed method displayed good linearity in the concentration range of 20-2000 ng mL-1 with the limit of 0.79 ng mL-1. The repeatability coefficient of variation (CV) for col-IV detection ranged from 3.16% to 7.50%. The col-IV level in samples collected from a hospital was assessed by the chemiluminescence assay. Satisfactory recoveries were obtained ranging from 93.30% to 100.14%. In conclusion, the magnetic bead-based chemiluminescence assay may be used as a routine and efficient tool to detect type IV collagen in clinical diagnosis.


Assuntos
Colágeno Tipo IV , Luminescência , Humanos , Fibrose , Cirrose Hepática , Imunoensaio/métodos
13.
Luminescence ; 39(3): e4723, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38516725

RESUMO

The investigation of thermoluminescence (TL) glow curves in liquid crystalline side chain N-phenyl-substituted phenyl polysiloxane hydroxamic acids (PHAs) has yielded significant insights. These polymers demonstrated TL behavior when exposed to ß-radiation between 0 and 220°C, indicating inherent luminescent properties when irradiated. Notably, a dose-dependent relationship was observed in reported derivatized polymers; this study elucidates the diverse TL characteristics exhibited by various liquid crystalline side chain N-phenyl-substituted phenyl PHAs when exposed to ß-radiation. Understanding these dose-dependent and dose-independent behaviors enhances the knowledge of their luminescent properties and potential applications in radiation detection.


Assuntos
Luminescência , Siloxanas , Dosimetria Termoluminescente
14.
J Clin Lab Anal ; 38(4): e25011, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38491776

RESUMO

BACKGROUND: To establish a chemiluminescence method for detecting anti-E1 and anti-E2 antibodies in the serum of patients with hepatitis C virus (HCV) infection. METHODS: The microplate was coated with recombinant envelope proteins E1 and E2 by indirect method, respectively, and the kits for detecting anti-E1 and anti-E2 antibodies were prepared. The methodological indexes were evaluated. RESULTS: The methodological indexes of the kits were as follows: precision test (the variation coefficient of anti-E1 antibody 6.71%-8.95% for within run and 9.91%-12.16% for between run, the variation coefficient of anti-E2 antibody 6.06%-8.44% for within run and 10.77%-13.98% for between run, respectively). The blank limit and detection limit were 1.18 RLIR and 3.16 RLIR for the anti-E1 antibody, and 1.26 RLIR and 3.32 RLIR for the anti-E2 antibody, respectively. The correlation coefficients (r) of anti-E1 and anti-E2 were 0.9963 and 0.9828, the analysis and measurement ranges (AMR) were 1.66-41.28 RLIR and 1.55-19.46 RLIR, and the average recovery was 96.4% and 93.7%, respectively. The rheumatoid factor and other positive serum samples had no interference or cross-reaction to the test, and the kits were stable within 15 months. The positive rates of anti-E1 and anti-E2 antibodies in 45 patients with HCV infection were 35.6% (16/45) and 44.4% (20/45), respectively. CONCLUSIONS: The kits for detecting anti-E1 and anti-E2 meet the requirements of methodology, and can be used in screening diagnosis, disease monitoring, prognosis evaluation, disease mechanism, and epidemiological studies of HCV infection. The HCV envelope proteins E1 and E2 have an immune response in HCV-infected patients.


Assuntos
Hepacivirus , Hepatite C , Humanos , Luminescência , Anticorpos Anti-Hepatite C , Anticorpos , Proteínas Recombinantes , Proteínas do Envelope Viral
15.
Sci Adv ; 10(10): eadk1992, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38457503

RESUMO

The fungal bioluminescence pathway can be reconstituted in other organisms allowing luminescence imaging without exogenously supplied substrate. The pathway starts from hispidin biosynthesis-a step catalyzed by a large fungal polyketide synthase that requires a posttranslational modification for activity. Here, we report identification of alternative compact hispidin synthases encoded by a phylogenetically diverse group of plants. A hybrid bioluminescence pathway that combines plant and fungal genes is more compact, not dependent on availability of machinery for posttranslational modifications, and confers autonomous bioluminescence in yeast, mammalian, and plant hosts. The compact size of plant hispidin synthases enables additional modes of delivery of autoluminescence, such as delivery with viral vectors.


Assuntos
Luminescência , Plantas , Animais , Mamíferos
16.
Angew Chem Int Ed Engl ; 63(17): e202401032, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38438340

RESUMO

Chiral nanoscale enantiomers exhibit different biological effects in living systems. However, their chirality effect on the detection sensitivity for chiral biological targets still needs to be explored. Here, we discovered that Co2+ can modulate the luminescence performance of L/D-glutathione (GSH)-modified copper nanoclusters (L/D-Cu NCs) and induce strong chiroptical activities as the asymmetric factor was enhanced 223-fold with their distribution regulating from the ultraviolet to visible region. One Co2+ coordinated with two GSH molecules that modified on the surface of Cu NCs in the way of CoN2O2. On this basis, dual-modal chiral and luminescent signals of Co2+ coordinated L/D-Cu NCs (L/D-Co-Cu NCs) were used to detect the chiral adenosine triphosphate (ATP) based on the competitive interaction between surficial GSH and ATP molecules with Co2+. The limits of detection of ATP obtained with fluorescence and circular dichroism intensity were 9.15 µM and 15.75 nM for L-Co-Cu NCs, and 5.35 µM and 4.69 nM for D-Co-Cu NCs. This demonstrated that selecting suitable chiral configurations of nanoprobes effectively enhances detection sensitivity. This study presents not only a novel method to modulate and enhance the chiroptical activity of nanomaterials but also a unique perspective of chirality effects on the detection performances for bio-targets.


Assuntos
Cobre , Nanoestruturas , Trifosfato de Adenosina , Luminescência , Glutationa
17.
ACS Appl Bio Mater ; 7(4): 2460-2471, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38517347

RESUMO

Here, we demonstrate a label-free dual optical response strategy for the detection of cytochrome c (Cyt c) with ultrahigh sensitivity using highly luminescent lanthanides containing inorganic-organic hybrid nanotubular sensor arrays. These sensor arrays are formed by the sequential incorporation of the photosensitizers 2,3-dihydroxynaphthalene (DHN) or 1,10-phenanthroline (Phen), and trivalent lanthanide terbium ions (Tb3+) into sodium lithocholate (NaLC) nanotube templates. Our sensing platform relies on the detection and quantification of Cyt c in solution by providing dual photoluminescence quenching responses from the nanotubular hybrid arrays in the presence of Cyt c. The large quenching of the sensitized Tb3+ emission within the DHN/Phen-Tb3+-NaLC nanotubular sensor arrays caused by the strong binding of the photosensitizers to Cyt c provides an important signal response for the selective detection of Cyt c. This long-lived lanthanide emission response-based sensing strategy can be highly advantageous for the detection of Cyt c in a cellular environment eliminating background fluorescence and scattering signals through time-gated measurements. The DHN containing nanotubular sensor arrays (DHN-NaLC and DHN-Tb3+-NaLC) provide an additional quenching response characterized by a unique spectral valley splitting with quantized quenching dip on the DHN fluorescence emission. This spectral quenching dip resulting from efficient FRET between the protein bound DHN photosensitizer and the heme group of Cyt c serves as an important means for specific detection and quantification of Cyt c in the concentration range of 0-30 µM with a low detection limit of around 20 nM.


Assuntos
Elementos da Série dos Lantanídeos , Elementos da Série dos Lantanídeos/química , Citocromos c , Fármacos Fotossensibilizantes , Térbio/química , Luminescência
18.
ACS Nano ; 18(13): 9431-9442, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38507745

RESUMO

The simultaneous pursuit of accelerative radiative and restricted nonradiative decay is of tremendous significance to construct high-luminescence-efficiency fluorophores in the second near-infrared wavelength window (NIR-II), which is seriously hindered by the energy gap laws. Herein, a mash-up strategy of π-extension and deuteration is proposed to efficaciously ameliorate the knotty problem. By extending the π-conjugation of the aromatic fragment and introducing an isotope effect to the aggregation-induced emission luminogen (AIEgen), an improved oscillator strength (f), coupled with suppressed deformation and high-frequency oscillation in the excited state, are successively implemented. In this case, a faster rate of radiative decay (kr) and restricted nonradiative decay (knr) are simultaneously achieved. Moreover, the preeminent emissive property of AIEgen in the molecular state could be commendably inherited by the aggregates. The corresponding NIR-II emissive AIEgen-based nanoparticles display high brightness, large Stokes shift, and superior photostability simultaneously, which can be applied for image-guided cancer and sentinel lymph node (SLN) surgery. This work thus provides a rational roadmap to improve the luminescence efficiency of NIR-II fluorophores for biomedical applications.


Assuntos
Nanopartículas , Neoplasias , Cirurgia Assistida por Computador , Humanos , Luminescência , Neoplasias/patologia , Nanopartículas/química
19.
Biomolecules ; 14(3)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38540791

RESUMO

In order to evaluate the role of substituents at 3-C and 17-C in the cytotoxic and cytoprotective actions of DHEA and 5-AED molecules, their derivatives were synthesized by esterification using the corresponding acid anhydrides or acid chlorides. As a result, seven compounds were obtained: four DHEA derivatives (DHEA 3-propionate, DHEA 3-butanoate, DHEA 3-acetate, DHEA 3-methylsulfonate) and three 5-AED derivatives (5-AED 3-butanoate, 5-AED 3,17-dipropionate, 5-AED 3,17-dibutanoate). All of these compounds showed micromolar cytotoxic activity toward HeLa and K562 human cancer cells. The maximum cytostatic effect during long-term incubation for five days with HeLa and K562 cells was demonstrated by the propionic esters of the steroids: DHEA 3-propionate and 5-AED 3,17-dipropionate. These compounds stimulated the growth of normal Wi-38 cells by 30-50%, which indicates their cytoprotective properties toward noncancerous cells. The synthesized steroid derivatives exhibited antioxidant activity by reducing the production of reactive oxygen species (ROS) by peripheral blood mononuclear cells from healthy volunteers, as demonstrated in a luminol-stimulated chemiluminescence assay. The highest antioxidant effects were shown for the propionate ester of the steroid DHEA. DHEA 3-propionate inhibited luminol-stimulated chemiluminescence by 73% compared to the control, DHEA, which inhibited it only by 15%. These data show the promise of propionic substituents at 3-C and 17-C in steroid molecules for the creation of immunostimulatory and cytoprotective substances with antioxidant properties.


Assuntos
Androstenodiol , Desidroepiandrosterona , Humanos , Desidroepiandrosterona/farmacologia , Luminol , Leucócitos Mononucleares , Voluntários Saudáveis , Células K562 , Luminescência , Propionatos , Esteroides
20.
Spectrochim Acta A Mol Biomol Spectrosc ; 313: 124114, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38447441

RESUMO

A ratiometric luminescent probe was fabricated using adenosine monophosphate (AMP) as a bridging ligand and 3-carboxyphenylboronic acid (3-CPBA) as the sensitizer and functional ligand that allowed the probe to recognize hydrogen peroxide (H2O2). The probe was labeled AMP-Tb/3-CPBA. Adding H2O2 caused the nonluminescent 3-CPBA to be converted into 3-hydroxybenzoic acid, which strongly luminesces at 401 nm. This meant that adding H2O2 decreased the AMP-Tb/3-CPBA luminescence intensity at 544 nm and caused luminescence at 401 nm. The 401 and 544 nm luminescence intensity ratio (I401/I544) was strongly associated with the H2O2 concentration between 0.1 and 60.0 µM, and the detection limit was 0.23 µM. Dual emission reverse-change ratio luminescence sensing using the probe allowed environmental effects to be excluded and the assay to be very selective. We believe that the results pave the way for the development of new functionalized lanthanide coordination polymers for use in luminescence assays.


Assuntos
Polímeros , Térbio , Peróxido de Hidrogênio , Luminescência , Ligantes , Monofosfato de Adenosina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...